Use of Thyroid Shield in Cone-Beam Computed Tomography: A Literature Review
PDF
HTML
EPUB

Keywords

Radiation protection; Cone-beam computed tomography; Guideline; Radiation, Ionizing; Thyroid gland; Radiography, Dental; Radiation dosage. Protección radiológica; Tomografía computarizada de haz cónico; Guía; Radiación ionizante; Glándula tiroides; Radiografía dental; Dosis de radiación.

How to Cite

Carrasco M., A., Barba R., L., & Hidalgo R., A. (2025). Use of Thyroid Shield in Cone-Beam Computed Tomography: A Literature Review. Odovtos - International Journal of Dental Sciences, 23–34. https://doi.org/10.15517/ijds.2025.65020

Abstract

The aim of this literature review was to analyze the evidence and international recommendations on the use of thyroid shield (TS) in cone-beam computed tomography (CBCT) examinations. The search was conducted in three electronic databases (PubMed, Scopus, and Web of Science) in English from 2010 to date. This search included articles that provided recommendations or benefits of TS use in CBCT, as well as those that discouraged its use. A complementary search was conducted by reviewing guidelines, recommendations, or articles from international organizations and globally recognized journals, published on their official websites. Of the 23 articles reviewed, 19 indicate that using TS in CBCT reduces radiation doses in patients or recommend its use in these examinations, as it provides a benefit to the patient. However, some note specific cases where its use is not advised. On the other hand, two articles, from the British Institute of Radiology and the UK Health Security Agency, do not recommend the use of TS in CBCT examinations, except in specific cases. Finally, two articles, both from the American Dental Association, oppose TS use in all maxillofacial radiographic examinations, including CBCT. Although there is no consensus among the reviewed articles regarding recommendations or benefits of TS use in CBCT examinations, most articles indicate that it reduces ionizing radiation doses or recommend its use. However, in some cases, TS use may interfere with image quality, making deciding whether to use TS in CBCT examinations challenging for the operator.

https://doi.org/10.15517/ijds.2025.65020
PDF
HTML
EPUB

References

Arai Y., Tammisalo E., Iwai K., Hashimoto K., Shinoda K. Development of a compact computed tomographic apparatus for dental use. Dentomaxillofac Radiol. 1999; 28 (4): 245-8.

Mozzo P., Procacci C., Tacconi A., Martini P.T., Andreis I.A. A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol. 1998; 8 (9): 1558-64.

Scarfe W.C., Farman A.G. What is cone-beam CT and how does it work? Dent Clin North Am. 2008; 52 (4): 707-30, v.

Ludlow J.B., Timothy R., Walker C., Hunter R., Benavides E., Samuelson D.B., et al. Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol. 2015; 44 (1): 20140197.

European Commission. European guidelines on radiation protection in dental radiology: the safe use of radiographs in dental practice. Publications Office. 2004 [Accessed 06 March 2025]. Available from: https://op.europa.eu/en/publication-detail/-/publication/ea20b522-883e-11e5-b8b7-01aa75ed71a1

European Commission. Evidence-based guidelines on cone beam CT for dental and maxillofacial radiology. Office for Official Publications of the European Communities. Radiation Protection 172. 2012 [Accessed 06 March 2025]. Available from: http://ec.europa.eu/energy/nuclear/radiation_protection/doc/publication/172.pdf

Pauwels R., Horner K., Vassileva J., Rehani M.M. Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use. Dentomaxillofac Radiol. 2019; 48 (7): 20190014.

Terashima S., Sano J., Osanai M., Toshima K., Ohuchi K., Hosokawa Y. Monte Carlo simulations of organ and effective doses and dose-length product for dental cone-beam CT. Oral Radiol. 2024; 40 (1): 37-48.

Hidalgo A., Davies J., Horner K., Theodorakou C. Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom. Dentomaxillofac Radiol. 2015; 44 (3): 20140285.

International Commission on Radiological Protection. The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103 2007 [Accessed 06 March 2025]. Available from: https://www.icrp.org/docs/icrp_publication_103-annals_of_the_icrp_37(2-4)-free_extract.pdf

National Research Council of the National Academies. Health risks from exposure to low levels of ionizing radiation: BEIR VII Phase 2 Washington, DC: The National Academies Press; 2006 [Accessed 06 March 2025]. Available from: https://nap.nationalacademies.org/catalog/11340/health-risks-from-exposure-to-low-levels-of-ionizing-radiation

Ludlow J.B., Walker C. Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography. Am J Orthod Dentofacial Orthop. 2013; 144 (6): 802-17.

Jaju P.P., Jaju S.P. Cone-beam computed tomography: Time to move from ALARA to ALADA. Imaging Sci Dent. 2015; 45 (4): 263-5.

Oenning A.C., Jacobs R., Pauwels R., Stratis A., Hedesiu M., Salmon B., et al. Cone-beam CT in paediatric dentistry: DIMITRA project position statement. Pediatr Radiol. 2018; 48 (3): 308-16.

Hidalgo-Rivas J.A., Theodorakou C., Carmichael F., Murray B., Payne M., Horner K. Use of cone beam CT in children and young people in three United Kingdom dental hospitals. Int J Paediatr Dent. 2014; 24 (5): 336-48.

Benavides E., Bhula A., Gohel A., Lurie A.G., Mallya S.M., Ramesh A., et al. Patient shielding during dentomaxillofacial radiography: Recommendations from the American Academy of Oral and Maxillofacial Radiology. J Am Dent Assoc. 2023; 154 (9): 826-35.e2.

Benavides E., Krecioch J.R., Connolly R.T., Allareddy T., Buchanan A., Spelic D., et al. Optimizing radiation safety in dentistry: Clinical recommendations and regulatory considerations. J Am Dent Assoc. 2024; 155 (4): 280-93.e4.

Cascante-Sequeira D., Barba Ramírez L., Ruiz-Imbert A. The use of thyroid shielding and lead apron in dentistry. Position Statement from the Costa Rican Academy of Oral and Maxillofacial Radiology. Odovtos-Int J Dent Sc. 2024; 26 (3): 10-9.

Qu X., Li G., Zhang Z., Ma X. Thyroid shields for radiation dose reduction during cone beam computed tomography scanning for different oral and maxillofacial regions. Eur J Radiol. 2012; 81 (3): e376-80.

International Atomic Energy Agency. Radiation protection in dental radiology, safety reports series No. 108. Vienna. 2022 [Accessed 06 March 2025]. Available from: https://www.iaea.org/publications/14720/radiation-protection-in-dental-radiology

British Institute of Radiology. Guidance on using shielding on patients for diagnostic radiology applications. 2020 [Accessed 05 October 2024]. Available from: www.bir.org.uk

National Council on Radiation Protection and Measurements. Radiation protection in dentistry and oral & maxillofacial imaging: recommendations of the National Council on Radiation Protection and Measurements. NCRP Report No. 177: National Council on Radiation Protection and Measurements; 2019 [Accessed 06 March 2025]. Available from: https://ncrponline.org/shop/reports/report-no-177/

Schneider A.B., Kaplan M.M., Mihailescu D.V. Thyroid Collars in Dental Radiology: 2021 Update. Thyroid. 2021; 31 (9): 1291-6.

Hiles P., Gilligan P., Damilakis J., Briers E., Candela-Juan C., Faj D., et al. European consensus on patient contact shielding. Insights Imaging. 2021; 12 (1): 194.

American Thyroid Association. Policy statement on thyroid shielding during diagnostic medical and dental radiology 2013 [Accessed 06 March 2025]. Available from: https://www.thyroid.org/wp-content/uploads/statements/ABS1223_policy_statement.pdf

White S.C., Scarfe W.C., Schulze R.K., Lurie A.G., Douglass J.M., Farman A.G., et al. The Image Gently in Dentistry campaign: promotion of responsible use of maxillofacial radiology in dentistry for children. Oral Surg Oral Med Oral Pathol Oral Radiol. 2014; 118 (3): 257-61.

United Kingdom Health Security Agency. Guidance on the safe use of dental cone beam CT (computed tomography) equipment. HPA-CRCE-010 2010 [Accessed 06 March 2025]. Available from: https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/340159/HPA-CRCE-010_for_website.pdf

Grüning M., Koivisto J., Mah J., Bumann A. Impact of thyroid gland shielding on radiation doses in dental cone beam computed tomography with small and medium fields of view. Oral Surg Oral Med Oral Pathol Oral Radiol. 2022; 134 (2): 245-53.

Attaia D., Ting S., Johnson B., Masoud M.I., Friedland B., Abu El Fotouh M., et al. Dose reduction in head and neck organs through shielding and application of different scanning parameters in cone beam computed tomography: an effective dose study using an adult male anthropomorphic phantom. Oral Surg Oral Med Oral Pathol Oral Radiol. 2020; 130 (1): 101-9.

Goren A.D., Prins R.D., Dauer L.T., Quinn B., Al-Najjar A., Faber R.D., et al. Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom. Dentomaxillofac Radiol. 2013; 42 (6): 20120260.

Qu X.M., Li G., Sanderink G.C., Zhang Z.Y., Ma X.C. Dose reduction of cone beam CT scanning for the entire oral and maxillofacial regions with thyroid collars. Dentomaxillofac Radiol. 2012; 41 (5): 373-8.

Vogiatzi T., Menz R., Verna C., Bornstein M.M., Dagassan-Berndt D. Effect of field of view (FOV) positioning and shielding on radiation dose in paediatric CBCT. Dentomaxillofac Radiol. 2022; 51 (6): 20210316.

Van Acker J.W.G., Pauwels N.S., Cauwels R.G.E.C., Rajasekharan S. Outcomes of different radioprotective precautions in children undergoing dental radiography: a systematic review. Eur Arch Paediatr Dent. 2020; 21 (4): 463-508.

Tsapaki V. Radiation protection in dental radiology - Recent advances and future directions. Phys Med. 2017; 44: 222-6.

Sarıbal G., Canger E.M., Yaray K. Evaluation of the radiation protection effectiveness of a lead-free homopolymer in cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2023; 136 (1): 91-101.

Chen G., Yin Y., Sun L., Tang Z., Chen J. Monte Carlo simulation study of the effect of thyroid shielding on radiation dose in dental cone beam CT in an adult male phantom. Radiat Prot Dosimetry. 2024.

American Dental Association, US Department of Health and Human Services. Dental radiographic examinations: recommendations for patient selection and limiting radiation exposure. 2012 [Accessed 06 March 2025]. Available from: https://www.ada.org/resources/ada-library/oral-health-topics/x-rays-radiographs

Memon A., Rogers I., Paudyal P., Sundin J. Dental x-rays and the risk of thyroid cancer and meningioma: a systematic review and meta-analysis of current epidemiological evidence. Thyroid. 2019; 29 (11): 1572-93.

International Atomic Energy Agency. Dosimetry in diagnostic radiology: an international code of practice. Vienna. 2007 [Accessed 06 March 2025]. Available from: https://www.iaea.org/publications/7638/dosimetry-in-diagnostic-radiology-an-international-code-of-practice

Fakhoury E., Provencher J.A., Subramaniam R., Finlay D. J. Not all lightweight lead aprons and thyroid shields are alike. J Vasc Surg. 2019; 70 (1): 246-50.

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

Copyright (c) 2025 Andrea Carrasco M., Lucía Barba R., Alejandro Hidalgo R.

Downloads

Download data is not yet available.